Doctor/Nurse Calling System
Automatic Controller for AMF & Standby Power Systems [with out U/V & O/V Protn.]
Custom-made Micro Controller based products
General Description
‘Doctor/Nurse Calling’ Unit [DCU] consists of :
- “Windows” to indicate Patient’s Room / Bed No. One Window for each Room/Bed is provided.
- Push Buttons for ‘ACCEPT’, ‘Lamp TEST’ & MUTE
- Built-in Audible Alarm.
- Each Room/Bed is provided with one ‘Call-Switch’ for use by the Patient
|
|
Application
In any Hospital it is essential to facilitate Patients to call the Duty Doctor/Staff Nurse/House-Keepers for attention /assistance during emergencies.
It is desirous that the ‘Doctor/Nurse Calling System’ be ‘Fool-Proof’ & attention to Patients is 100% assured, beyond ambiguity.
‘Doctor/Nurse Calling’ Unit [DCU] is usually mounted in a ‘Centralised-Area’, say ~ the ‘Duty-Room’ of Doctors/Nurses, in each floor of a Hospital.
- DCU announces the ‘Call from Patient’ by means of ‘Visual’ & ‘Audible’ Alarms, to alert the Duty Doctors/Nurses and to initiate remedial action.
- For ‘Visual’ Alarm, ‘Rear-Illuminated Windows’ are provided. Patient’s Room/Bed No. is inscribed on Front-side of Window.
- For ‘Audible’ Alarm, in-built ‘Buzzer’ is provided.
Method of Operation :
- To call Doctor/Nurse, Patient has to Press the Switch provided by his/her Bed-side.
- ‘Rear-Illuminated Window’ displaying Patient’s Room/Bed No., starts ‘Flashing’ & Audible Alarm switches ON, thus alerting the Doctor/Nurse.
- Doctor/Nurse should press ‘ACCEPT’ Push Button to acknowledge ‘Call’ from the Patient.
- ‘Flashing’ Window become ‘Steady’ glow & Audible Alarm switches OFF.
- Doctor/Nurse should go to Patient’s Room/Bed, attend to his/her needs and before returning should switch ‘OFF’ the Patient’s bed-side ‘Call-Switch’ to ‘RESET’ the ‘Call’ from Patient.
- As soon as ‘Call-Switch’ is switched OFF, ‘Steady’ glow of Window on DCU is switched OFF, thereby completing the episode.
Technical Specifications
|
Operate Volts
Voltages |
85 to 275 V AC or DC |
|
Choice of Windows per DCU |
Min : 08 Windows per DCU
Max : Any No. of Windows per DCU |
|
Individual Window Size |
70mm x 35mm … [Default size] |
|
Operate Temp |
0C to 70C, Upto 95% RH |
|
Storage Temp |
-10 C to 90 C, Upto 95% RH |
|
Burden |
2.5 Watts @ 230 VAC [Max]
per DCU Window |
| Choice of Sequences of Operation |
[1]. Auto-RESET [AR-01]
[2]. Manual-RESET [MR-01 & MR-02]
[3]. Ringback [RBM-01] |
| Choice of
Switch Types
|
[1]. Regular ‘ON/OFF’ [Toggle type]
[2]. ‘Calling-Bell’ [Spring-Return type]
|
|
Note : Product improvement is a continuous feature. Specifications / Design listed in this publication are therefore subject to revision, without notice.
|